電氣

 

 

 

Electrical

 

 

 

 

 

問題

 

 

 

Items

 

 

 

 

 

建議

 

 

 

Suggestions

 

 

 

 

 

1

 

 

 

 

實驗室內的電源容量過小,不能滿足儀器的供電要求,尤其要重點核查理化實驗室和洗消間,必須保證這些(每間)實驗室有三相電源,最小容量不能低于10kW Low volume of power will not satisfy the power supply of equipments, especially for physical and chemistry lab and wash-infection room,  it should be ensured that labs have three-phase power and its minimum volume should not below 10KW.

 

 

 

 

 

 

 

 

2

 

 

 

 

接地端子箱的設置,要求每間實驗室,尤其是理化實驗室必須設置接地端子箱,且接地電阻不得大于1歐姆
                            Every lab, especially physical chemistry lab should have grounding terminal board and grounding resistance should no more than 1Ω.

 

 

 

 

必須滿足要求,設置專用的接地干線和端子箱
                            It should install grounding main burbar and terminal board.

 

 

 

 

3

 

 

 

 

實驗室燈具,不得采用鏈吊式安裝,應采用吸頂式
                             The lightings in lab should not use chain to install and should connect ceiling directly.

 

 

 

 

建議改變燈具的排列方式,數量和安裝方式,采用吸頂安裝

 

 

 

Change the arrange style, amount and install style and adopt directly connection to ceiling.

 

 

 

 

 

4

 

 

 

 

所有二級生物安全實驗室的入口處應安裝顯示工作狀態的文字或燈光信號
                            The entrance of all the BSL2 should have signs and lighting signs which could show the working condition

 

 

 

 

 

 

 

 

5

 

 

 

 

生物安全實驗室內應設緊急發光疏散標志
                       
BSL should have emergency escape sign.

 

 

 

 

 

 

 

 

6

 

 

 

 

如有集中的氣瓶間,則該房間的電具要求采用防爆型. If there is integrated gas container room, the room should adopt flameproof device.

 

 

 

 

 

 

 

 

7

 

 

 

 

在生物安全實驗室區域設置火災自動報警裝置. BSL should have fire auto-alarm.

 

 

 

 

建議采用區域報警設備,對生物安全實驗室進行火災預警
                            Local alarm device is preferred in order to give pre-alarm of fire.

 

 

 

 

8

 

 

 

 

進入生物實驗室的管路沒有做密閉,應采取措施,完成此步驟
                            The pipe which putted into bio lab should be pressurized.

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

插座沒有配置防水罩,建議補加

 

 

 

Socket should be equipped with water-proof cover.

 

 

 

 

 

10

 

 

 

 

 

 

 

 

如存在血清存儲、必須冷藏的試劑或是疫苗庫,建議提供備用電源.

 

 

 

If there are serum storage, vaccine storage, reagent which should be refrigeration and vaccine storage, back-up power should be provide. 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

如有負壓二級生物安全實驗室提供一條備用電源. BSL2 should have one back-up power.

 

 

 

 

12

 

 

 

 

 

 

 

 

生物安全實驗室內的電源設置漏電檢測報警裝置  The power supply of BSL should have leakage alarm device.

 